<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>By Vendor |</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/</link><atom:link href="https://www.teksyn.net/guides/building-automation/by-vendor/index.xml" rel="self" type="application/rss+xml"/><description>By Vendor</description><generator>HugoBlox Kit (https://hugoblox.com)</generator><language>en-us</language><lastBuildDate>Tue, 30 Dec 2025 00:00:00 +0000</lastBuildDate><image><url>https://www.teksyn.net/media/logo.svg</url><title>By Vendor</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/</link></image><item><title>Alerton</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/alerton/alerton/</link><pubDate>Tue, 30 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/alerton/alerton/</guid><description>&lt;h3 id="target-legacy-alerton-system-could-consist-of"&gt;&lt;strong&gt;Target Legacy Alerton System could consist of:&lt;/strong&gt;&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;BCM-Eth Controller&lt;/li&gt;
&lt;li&gt;BCM-TUX Gateway&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="integration-trunks"&gt;&lt;strong&gt;Integration trunks:&lt;/strong&gt;&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;BACnet MS/TP&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="legacy-devices"&gt;Legacy devices:&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;VAV&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="mstp-devices"&gt;MSTP devices:&lt;/h3&gt;
&lt;p&gt; &lt;/p&gt;
&lt;h3 id="software-tools"&gt;Software tools:&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;Envision&lt;/li&gt;
&lt;li&gt;Compass​&lt;/li&gt;
&lt;/ul&gt;</description></item><item><title>Automated Logic Corporation (ALC)</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/automated-logic-corporation/automated-logic-corporation-alc/</link><pubDate>Mon, 15 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/automated-logic-corporation/automated-logic-corporation-alc/</guid><description/></item><item><title>Carrier</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/carrier/carrier/</link><pubDate>Mon, 15 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/carrier/carrier/</guid><description/></item><item><title>Honeywell</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/honeywell/honeywell/</link><pubDate>Mon, 15 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/honeywell/honeywell/</guid><description>&lt;p&gt;Default Passwords&lt;/p&gt;
&lt;p&gt;honeywell/webs&lt;/p&gt;
&lt;p&gt;honeywell/websn4&lt;/p&gt;
&lt;p&gt;honeywell/niagara&lt;/p&gt;
&lt;p&gt;Honeywell/websn4&lt;/p&gt;</description></item><item><title>Johnson Controls (JCI)</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/johnson-controls/johnson-controls-jci/</link><pubDate>Mon, 15 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/johnson-controls/johnson-controls-jci/</guid><description>&lt;p&gt;Targeted JCI legacy system could consist of:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;ADS&lt;/li&gt;
&lt;li&gt;ADX&lt;/li&gt;
&lt;li&gt;NAE&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Integration trunks:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;N2 Trunk&lt;/li&gt;
&lt;li&gt;BACnet MSTP&lt;/li&gt;
&lt;li&gt;​BACnet IP&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Legacy N2 devices:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;VAV&lt;/li&gt;
&lt;li&gt;UNT&lt;/li&gt;
&lt;li&gt;VMA&lt;/li&gt;
&lt;li&gt;AHU&lt;/li&gt;
&lt;li&gt;DX 9100&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;MSTP devices:  &lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;​FEC&lt;/li&gt;
&lt;li&gt;Software tools:&lt;/li&gt;
&lt;li&gt;SCT – System Configuration Tool&lt;/li&gt;
&lt;li&gt;​CCT – Controller Configuration Tool&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Purposes&lt;/p&gt;
&lt;p&gt;Document various how to procedures to assist with on-boarding JCI legacy system for Digital Command Performance Services&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Show how to use different JCI SW Tools to extract information from the JCI System&lt;/li&gt;
&lt;li&gt;Show how to use a generic BACnet Browser to extract information from the JCI system&lt;/li&gt;
&lt;li&gt;Show how to extract state-text tables (for multi-state values) from the JCI system&lt;/li&gt;
&lt;li&gt;Show how to setup and use MSIB (Windows and X300-MSIB versions) to discover BACnet objects from the JCI system and send values to Navigator&lt;/li&gt;
&lt;li&gt;Show how Desigo CC can discover BACnet objects at the JCI system&lt;/li&gt;
&lt;li&gt;Show how Desigo Optics can discover BACnet objects at the JCI system&lt;/li&gt;
&lt;li&gt;Show how to create/load JCI N2 ISB Apps to the BACnet PX controller with N2 Master Integration driver&lt;/li&gt;
&lt;li&gt;​​Please always consult respective technical manuals for details.  Several manuals are listed in the Resources Section.&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Internal Resources&lt;/p&gt;
&lt;h3 id="jci-n2-master-integration-driver"&gt;​​JCI N2 Master Integration Driver&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;Johnson Controls N2 Master Driver of PXC Modular and PXC-36 Technical Manual – 140-0802 2018-12-14&lt;/li&gt;
&lt;li&gt;Johnson Controls N2 Master Driver Release/Upgrade Notes – 126-978 2019-11-08&lt;/li&gt;
&lt;li&gt;User’s Guide Application Builder User Guide – 140-0574 2020-02-05&lt;/li&gt;
&lt;li&gt;​Application Builder: Newer Versions of Integration Drivers Missing from the “Select Driver” List When Creating a New ISB File – Field Support Article by Mazhar Paliwala&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="bt-university"&gt;BT University&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;Training manual for SPC-501 – Digital Command Performance JCI&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="dxr"&gt;​DXR&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;P1 DXR TEC VAV and Fan Powered Box Migration – A6V11504404 2019-07-11&lt;/li&gt;
&lt;li&gt;DXR2 FPB Start-Up procedure – A6V10665938&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="msib"&gt;MSIB&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;Siemens MSIB User Guide Version 3.2&lt;/li&gt;
&lt;li&gt;​Siemens MSIB User Guide Version 2.8.1​&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;External Resources&lt;/p&gt;
&lt;h3 id="johnson-controls-system-documentation"&gt;​Johnson Controls System Documentation&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;Metasys SCT System Configuration Tool Help Doc Number LIT-12011964&lt;/li&gt;
&lt;li&gt;HVACPro User Guide April 2001&lt;/li&gt;
&lt;li&gt;Metasys System Configuration Guide LIT-12011832 2020-08-12&lt;/li&gt;
&lt;li&gt;Metasys SCT: System Configuration Tool Help LIT-12011964 2020-01-21&lt;/li&gt;
&lt;li&gt;NAE Commissioning Guide LIT-1201519 2019-10-14&lt;/li&gt;
&lt;li&gt;FEC26 Field Equipment Controllers Installation Guide Part No 24-10143-144 Rev M 2019-10-18&lt;/li&gt;
&lt;li&gt;Controller Configuration Tool Help LIT-12011147 2019-12-04​&lt;/li&gt;
&lt;li&gt;BACNet Integration Tech Bulletin - LIT-1201531&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;Accessing Metasys &lt;/p&gt;
&lt;p&gt;1. Locate the icon for Launcer on the Metasys System. If you are logging into a server and you attempt to open Launcher and it does not open it is because only one use may have launcher open at a time (Note Metasys), ask all other users to close launcher and it will open.  &lt;/p&gt;
&lt;p&gt;2. Running Launcher and select the SMP tab, in the example below there are two devices to login to. Be sure to select the ADX server.  &lt;/p&gt;
&lt;p&gt;3. After selecting the server to login to you will be prompted to login.  &lt;/p&gt;
&lt;p&gt;4. After login you will see the main window of Metasys.&lt;/p&gt;</description></item><item><title>Trane</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/trane/trane/</link><pubDate>Mon, 15 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/trane/trane/</guid><description>&lt;p&gt;Trane System(s) could consist of:&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;Enhanced BCU (BMTS)&lt;/li&gt;
&lt;li&gt;Enhanced BCU (BMTW)&lt;/li&gt;
&lt;li&gt;Enhanced BCU (BMTX)​&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="integration-trunks"&gt;Integration trunks:&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;COM3&lt;/li&gt;
&lt;li&gt;COM4/LON&lt;/li&gt;
&lt;li&gt;BACnet MS/TP&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="legacy-com3com4-devices"&gt;Legacy COM3/COM4 devices:&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;VAV&lt;/li&gt;
&lt;li&gt;DAC&lt;/li&gt;
&lt;/ul&gt;
&lt;h3 id="mstp-devices"&gt;MSTP devices:&lt;/h3&gt;
&lt;p&gt; &lt;/p&gt;
&lt;h3 id="software-tools"&gt;Software tools:&lt;/h3&gt;
&lt;ul&gt;
&lt;li&gt;Tracer TU&lt;/li&gt;
&lt;li&gt;Trane BACnet Setup Tool&lt;/li&gt;
&lt;/ul&gt;</description></item><item><title>Tridium Niagara</title><link>https://www.teksyn.net/guides/building-automation/by-vendor/tridium-niagara/tridium-niagara/</link><pubDate>Mon, 15 Dec 2025 00:00:00 +0000</pubDate><guid>https://www.teksyn.net/guides/building-automation/by-vendor/tridium-niagara/tridium-niagara/</guid><description/></item></channel></rss>